ROTISZINT®HighCapacity, 500 ml
Boiling point (bp) 305 °C
Flash point (flp) 149 °C
Melting point (mp) <-30 °C
Storage temp. +15 to +25 °C
ADR 9 III
WGK 3
UN-Nr. 3082
Multi-purpose, ready-to-use scintillation cocktails for Liquid Scintillation Counting (LSC) of β radiators (e.g. 3H, 14C, 32P, 35S) in aqueous samples. NPE-free
- High counting efficiency
- Very good quench resistance
- High flash point
- NPE free
- Biodegradable
- Non-carcinogenic
- According to 2003/53/ECC
The next generation
ROTISZINT® Cocktails
have been developed to replace nonylphenylethoxylates (NPE) with more
user-friendly, sustainable reagents. In addition, these modern cocktails show
even higher scintillation efficiency and higher sample holding capacity.
ROTISZINT® cocktails
are also biodegradable and pleasant to use due to their high flash point.
ROTISZINT® scintillation
cocktails may be used in all biological, biochemical and chemical areas. Typical
applications are, for instance, the measurement of cell culture supernatants,
routine analysis, enzymatic or flow-count assays in the field of research,
development or analytics.
The cocktails are according to Directive
2003/53/ECC of the European Parliament and Council
Wide excitation
range between 190 and 370 nm
Emission maximum: 420-430
nm
Our
modern ROTISZINT® cocktails
contain the same reagents as primary and secondary scintillators that were used
in ROTISZINT®Eco
plus. Thus, neither the excitation nor the detection wavelength change for the
application.
We also recommend to use the same
scintillation protocol in the first approaches with one of the new ROTISZINT® cocktails
as was previously used with the cocktail Eco plus (0016). In many cases, the
parameters are directly transferable. If the scintillation results are not
satisfactory at first, the sample quantity (the ratio sample/cocktail) can be
readjusted.
ROTISZINT®HighCapacity ROTISZINT® ready-to-use, NPE free, for scintillation
ROTISZINT®HighCapacity
was developed to work with both dilute and more concentrated samples used in
general LSC counting. This special scintillation cocktail will accept up to 10
ml of most dilute sample types and lesser volumes of concentrated samples.
ROTISZINT®HighCapacity
thus offers the greatest possible flexibility with samples of high diversity.
Biodegradable.
- NPE free - environmentally safe and non-carcinogenic
- High counting efficiency
- Low photo- and chemoluminescence
- Very good colour- and chemical quench resistance
- Virtually odor- and colourless
- High flash point
- No permeation through plastic vials
The sample uptake capacity is up to 10 ml / 10 ml cocktail for many common solvents such as 0.5 M HNO3, 1 M H3PO4, 0.1 M NaOH, 0.1 M NaCl, PBS and water. Only for some special and highly concentrated solutions (such as 0.1 M ammonium citrate, 0.1 M EDTA, 4 M H3PO4 or 4 M HNO3) the maximum sample volume is 4 to 6 ml / 10 ml cocktail.
Excellent for measuring
solutions. For the measurement of filter samples we recommend the use of
ROTISZINT®Filter.