ROTISZINT®HighCapacity

Dostępność: Na zamówienie, realizacja około 2 tyg.
Cena brutto: 332,72 zł

Cena regularna:

332.72
Najniższa cena z 30 dni przed obniżką:
Cena netto: 270,50 zł

Cena regularna:

Najniższa cena z 30 dni przed obniżką:
ilość 500 ml

towar niedostępny

Dodaj do ulubionych
nr katalogowy: ROTH-1P1C.1

Opis

ROTISZINT®HighCapacity, 500 ml

ROTISZINT® ready-to-use, NPE free, for scintillation
Scintillation cocktail
Density (D) ~1 g/cm³
Boiling point (bp) 305 °C
Flash point (flp) 149 °C
Melting point (mp) <-30 °C
Storage temp. +15 to +25 °C
ADR 9 III
WGK 3
UN-Nr. 3082

LSC cocktail, for large sample volumes and highly concentrated samples
 

Multi-purpose, ready-to-use scintillation cocktails for Liquid Scintillation Counting (LSC) of β radiators (e.g. 3H, 14C, 32P, 35S) in aqueous samples. NPE-free

  • High counting efficiency
  • Very good quench resistance
  • High flash point
  • NPE free
  • Biodegradable
  • Non-carcinogenic
  • According to 2003/53/ECC

The next generation ROTISZINT® Cocktails have been developed to replace nonylphenylethoxylates (NPE) with more user-friendly, sustainable reagents. In addition, these modern cocktails show even higher scintillation efficiency and higher sample holding capacity. ROTISZINT® cocktails are also biodegradable and pleasant to use due to their high flash point.
ROTISZINT® scintillation cocktails may be used in all biological, biochemical and chemical areas. Typical applications are, for instance, the measurement of cell culture supernatants, routine analysis, enzymatic or flow-count assays in the field of research, development or analytics.

The cocktails are according to Directive 2003/53/ECC of the European Parliament and Council


Wskazówki dotyczące zastosowania

Wide excitation range between 190 and 370 nm
Emission maximum: 420-430 nm

Our modern ROTISZINT® cocktails contain the same reagents as primary and secondary scintillators that were used in ROTISZINT®Eco plus. Thus, neither the excitation nor the detection wavelength change for the application.
We also recommend to use the same scintillation protocol in the first approaches with one of the new ROTISZINT® cocktails as was previously used with the cocktail Eco plus (0016). In many cases, the parameters are directly transferable. If the scintillation results are not satisfactory at first, the sample quantity (the ratio sample/cocktail) can be readjusted.



ROTISZINT®HighCapacity ROTISZINT® ready-to-use, NPE free, for scintillation

ROTISZINT®HighCapacity was developed to work with both dilute and more concentrated samples used in general LSC counting. This special scintillation cocktail will accept up to 10 ml of most dilute sample types and lesser volumes of concentrated samples.
ROTISZINT®HighCapacity thus offers the greatest possible flexibility with samples of high diversity.
Biodegradable.

  • NPE free - environmentally safe and non-carcinogenic
  • High counting efficiency
  • Low photo- and chemoluminescence
  • Very good colour- and chemical quench resistance
  • Virtually odor- and colourless
  • High flash point
  • No permeation through plastic vials

The sample uptake capacity is up to 10 ml / 10 ml cocktail for many common solvents such as 0.5 M HNO3, 1 M H3PO4, 0.1 M NaOH, 0.1 M NaCl, PBS and water. Only for some special and highly concentrated solutions (such as 0.1 M ammonium citrate, 0.1 M EDTA, 4 M H3PO4 or 4 M HNO3) the maximum sample volume is 4 to 6 ml / 10 ml cocktail.


Zastosowanie

Excellent for measuring solutions. For the measurement of filter samples we recommend the use of ROTISZINT®Filter.

We recommend the use of ROTILABO®Dispensers.

 

Informacje techniczne

Max. poziom emisji 420 nm 
do góry
Sklep jest w trybie podglądu
Pokaż pełną wersję strony
Sklep internetowy Shoper Premium